"Established in the Year 2002, is an Original Equipment Manufacturer based in the Educational and Industrial Hub of Pune, India."
Sampling is one of the most critical aspects of any Gas Analysis system. The accuracy and reliability of your Gas Analyser is heavily dependent on the quality of the sample presented to it. At Sarvesh Analytics, we understand this dependency and offer a comprehensive range of Sampling Components designed to ensure your gas analyser receives a representative, clean, and conditioned sample at all times.
From Peltier-based Sample Coolers to Heated Sample Probes for high-temperature stack applications, our product range covers every aspect of the sample conditioning chain. We are also the Exclusive Distributor for Headline Filters Ltd. UK for the Indian subcontinent, offering world-class filtration solutions.
Our Sample Gas Coolers are Peltier-based and offer much more than a conventional Sample Gas Cooler. They are designed for precise dew point control and reliable condensate removal in continuous gas sampling systems, ensuring your analyser receives a dry, representative sample.
| Parameter | Specification |
|---|---|
| Cooling Method | Peltier (Thermoelectric) |
| Outlet Gas Temperature | +2°C to +5°C (typical) |
| Inlet Gas Temperature | Up to 80°C (standard) |
| Cooling Capacity | Model dependent |
| Condensate Drain | Auto-drain / Peristaltic pump option |
| Power Supply | 90-260 VAC, 50/60 Hz |
| Enclosure | Wall / Panel Mounted, IP65 |
A Complete Sample Handling System which meets all engineering and maintenance goals. Our Smart Sampling System integrates multiple sample conditioning components into a single, purpose-built enclosure — designed for seamless connectivity with your gas analyser.
| Feature | Description |
|---|---|
| System Type | Custom-engineered sample handling panel |
| Components | Filter + Cooler + Regulator + Flow Meter + Valves |
| Enclosure | SS316 / MS Powder Coated, IP65 |
| Area Classification | Safe Area / Hazardous Area (Ex-d / Ex-p options) |
| Sample Pressure | As per process (regulated internally) |
| Sample Temperature | Cooled to +2°C to +5°C at analyser inlet |
| Documentation | GA drawing, P&ID, I/O list, Manual |
Sample Gas Probes for stack applications — available as heated or unheated, with or without filter, in various Materials of Construction (MOCs). Designed to extract representative samples from high-temperature, high-dust process streams.
| Parameter | Heated Probe | Unheated Probe |
|---|---|---|
| Process Temperature | Up to 600°C | Up to 400°C |
| Heating Type | Electrical trace heating | N/A |
| Heating Temperature | Up to 200°C (controlled) | N/A |
| Filter Element | Sintered SS / Ceramic (2µm–40µm) | Sintered SS / Ceramic |
| Standard MOC | SS316L | SS316L |
| Probe Diameter | 1" / 1.5" / 2" NB | 1" / 1.5" / 2" NB |
| Mounting | Flanged (ANSI/DIN) | Flanged / Threaded |
| Back Purge | Optional | Optional |
A safe and easier solution for online removable sample probe from high pressure lines. Retractable probes allow insertion and removal of the probe without shutting down the process — critical for continuous plant operations.
| Parameter | Specification |
|---|---|
| Operation | Hot-tap retractable, no process shutdown |
| Line Pressure | Up to 40 bar (higher on request) |
| Sealing Mechanism | Integral double isolation valve |
| Retraction Method | Handwheel / pneumatic actuator |
| Filter Element | Sintered metal (in-situ replaceable) |
| Standard MOC | SS316L |
| Mounting | 1" NPT / Flanged (ANSI 150/300) |
| Purge Connection | 1/4" NPT for nitrogen purge |
The complete range of Filtration products from Headline Filters Ltd. UK. We are the Exclusive Distributor for the Indian subcontinent. Headline Filters are internationally recognized for high-quality coalescing and particulate filtration for gas and air applications.
| Filter Type | Application | Removal Rating |
|---|---|---|
| Coalescing | Liquid aerosol, oil mist, water | 0.01 µm (99.99%+) |
| Particulate | Dust, pipe scale, solids | 1 µm to 40 µm |
| Activated Carbon | Hydrocarbons, odours, vapours | By adsorption |
| Pre-Filter | Coarse contamination protection | 5 µm to 40 µm |
| High Pressure | High-pressure gas lines | Various grades |
PDF Document • Peltier Based Sample Gas Coolers
PDF Document • Complete Sample Handling Systems
PDF Document • Stack Application Sample Probes
PDF Document • Hot-Tap Retractable Probes
PDF Document • Headline Filters Ltd. UK Product Range